MAGNETIC CONTACT
DETECTORS
The Magnetic Contact Set comprises 2 parts; Detector
and Magnet. They are designed to be tted to either
doors or windows with the Magnet mounted on the
opening part of the door/window and the Detector
mounted to the frame.
When the protected door or window is opened and the
Magnet is moved away from the Detector an alarm will
be triggered, (if the system is Armed).
The Magnetic Contact Detector has the facility to
connect an additional wired Magnetic Contact. This
must be of a normally closed contact type with the
contact being opened in order to generate an alarm
condition.
The Magnetic Contact Detector is powered by two
CR2032 type Lithium cells which under normal
conditions will have an expected of approximately 1
year. Under normal battery conditions the LED on
the Detector will not illuminate when the Detector is
triggered, (unless the detector is in test mode with the
battery cover removed). However, under low-battery
conditions this LED will be illuminated for approximately
1 second when the detector is triggered. When this
occurs the batteries should be replaced as soon as
possible.
Any number of Magnetic Contact Detectors can be
used with the system, providing they are all coded with
the same system House Code and are mounted within
effective radio range of the Control Panel.
POSITIONING THE MAGNETIC CONTACT
DETECTORS
The Magnetic Contact Detector is suitable for mounting
in dry interior locations only.
Decide which doors and windows are to be protected
by tting Magnetic Contact Detectors, (usually the
front and back doors as a minimum will have Magnetic
Contact Detectors tted). However additional detectors
may be tted where required to other more vulnerable
doors or windows, (e.g. garage, patio/conservatory
doors etc.).
Ensure that the position selected for the Magnetic
Contact Detector is within effective range of the Control
Panel.
Do not x the Detector onto or very close to metalwork
(i.e. radiators, water pipes, etc.) as this could affect the
radio range of the device.
On PVC Door/Window frames, it may be necessary to
space the Detector and Magnet away from the metal
surface using a plastic or wooden spacer to achieve
the necessary radio range.
INSTALLING AND CONFIGURING THE
MAGNETIC CONTACT DETECTORS
Ensure that the system is in Test mode (see page 18).
1. Remove the battery cover by sliding and lifting it off.
(DO NOT use a screwdriver to lever it off).
2. The Detector and Magnet should be mounted
together along the opening edge of the Window/Door
opposite the hinges. Ensure that the parallel gap
between the Magnet and Detector is less than 10mm
and that the arrow on the magnet is aligned with the
mark on the detector.
The Detector should be mounted on the xed part of
the frame and the Magnet on the opening part.
The Detector and Magnet should be mounted using the
double sided adhesive pads or screws provided.
Note: If mounting the device using the adhesive pads
ensure that the mounting surfaces are clean and dry
before mounting.











