9. EXIT DELAY TONE
During the Exit delay period the Control Unit may be
set to either remain silent or to give an intermittent
bleep tone.
With the Control Unit in Programming mode Enter
.
Zone 1 LED will indicate the setting:-
LED ‘ON’ - intermittent bleep delay tone selected
LED ‘OFF’ - silent exit delay selected.
Factory default:-
intermittent bleep tone ON - Zone 1 LED ‘ON’.
Press to select silent exit delay
Press to select intermittent bleep delay tone.
Press to memorise the setting and revert to the
Programming mode.
10. QUICK ARM/PART ARM
Quick Arm allows the Control Unit to be Armed or
Part Armed by simply pressing and holding the Arm
or Part Arm key for 5 seconds removing the need to
enter an access code first.
With the Control Unit in Programming mode Enter
.
Zone 1 LED will indicate the setting:-
LED ‘OFF’ - Quick Arm ‘OFF’
LED ‘ON’ - Quick Arm ‘ON’
Factory default:-
Quick Arm OFF - Zone 1 LED ‘OFF’
Press to select Quick ARM ‘ON’
Press to select Quick ARM ‘OFF’
Press to memorise the setting and to revert to
the Programming mode.
11. JAMMING DETECTION SYSTEM
In order to detect any attempts to jam the radio channel
used with your alarm system a sophisticated Jamming
Detection system is incorporated into the Control Unit.
If this feature is selected and the radio channel is
continuously jammed for more than 30 seconds the
Control Unit sounder will emit a Pre Alarm series of
rapid bleeps for 5 seconds. If the system is Armed and
the Jamming continues for a further 10 seconds or
more; or a total of 30 seconds of Jamming is detected
within a 5 minute period, a full alarm will occur indicated
by the Internal and External alarms sounding, but no
Zone LED’s ON.
The jamming detection circuit is designed to
permanently scan for illegal jamming signals.
However, it is possible that it may detect other
local radio interference operating legally or illegally
on the same frequency. If it is planned to operate
the jamming detection feature we recommend that
the system is monitored for false jamming alarms
for at least 2 weeks prior to leaving the Jamming
Detect function on permanently.
With the Control Unit in Programming mode Enter
.
Zone 1 LED will indicate the setting:-
LED ‘OFF’ - Jamming Detection System ‘OFF’
LED ‘ON’ - Jamming Detection System ‘ON’
Factory default:-
Jamming Detection ‘OFF’, Zone 1 LED ‘OFF’.
Press to select Jamming Detection ‘ON’
Press to select Jamming Detection ‘OFF’
Press to memorise the setting and to revert to
the Programming mode.
12. SIREN CODE (AND OPTIONAL MEDICAL
ALERT PENDANT CODE)
A small radio transmitter is incorporated within the
RE5000S Control Unit to operate and control the
external Solar Siren & Strobe. To enable the
Control Unit to communicate with the external
Solar Siren & Strobe the Siren Code set in the
external Siren (see page 14) needs to be
programmed into the Control Unit.
The (optional) Medical Alert Pendant(s) to be used
with the system must also be set to the ‘Siren Code’
in order that the pendant radio signal is sent to both
the Control Unit and the external Siren & Strobe,