Response SL5 Instruções de Operação Página 28

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 27
Using a Remote Control
With the required House Code already
configured, press the button on the
Remote Control.
When the Control Panel receives the signal from
the Remote Control the Panel will beep and the
display will change to show the received house
code on lower line of the display beneath the
corresponding DIP switch numbers (1-8).
Press to save the new setting, or
Press to exit without saving.
Note: Make a note of the system house code now in
the Alarm Record section.
ALARM DURATION
Scroll through the menu until ‘2-2 ALARM TIME’ (and
the current setting) is displayed.
To change the setting press .
On/Off Status
Default setting: ON
Scroll through the menu until ‘2-2-1 Status’ (and
the current setting) is displayed.
To change the setting press .
Press to enable the Siren, or
Press to disable the Siren.
Siren Duration
Default setting: 180s
Scroll through the menu until ‘2-1-2 Time’ (and the
current setting) is displayed.
To change the setting press .
Enter the required alarm duration in units of
10s. e.g. enter 6 for a 60s alarm duration (max
setting 60, i.e. 600s/10mins).
Press to save and exit, or
Press to exit without saving.
Press to return to top level System Setup
menu.
Note: Following an alarm condition the Siren will
continue to sound until either the system is
Disarmed; or the Alarm Duration Time expires. If the
“3 minute alarm time limit” of the Solar Siren is
enabled then the Solar Siren will shut down after 3
minutes even if the panel siren is still operating.
WIREFREE SIREN
Allows the wirefree siren to be enabled or disabled.
Default setting: ON
Scroll through the menu until ‘2-3 Wirefree Siren’
(and the current setting) is displayed.
To change the setting press .
Press to enable the Solar Siren, or
Press to disable the Solar Siren.
JAMMING DETECTION
Allows the jamming detection in the control panel to
be enabled or disabled.
Default setting: OFF
Scroll through the menu until ‘2-4 RF Jamming
Detection’ (and the current setting) is displayed.
To change the setting press .
Press to enable Jamming Detection, or
Press to disable Jamming Detection.
CONTROL PANEL BACK LIGHT
This controls how long the display backlight will
remain illuminated for after a key is pressed.
Default setting: 10s
Scroll through the menu until ‘2-5 Back Light’ (and
the current setting) is displayed.
To change the setting press .
Press to save and exit, or
Press to exit without saving.
ALARM RELAY
This controls the operation of the NO/NC hardwired
output relay contacts following an alarm.
Default setting: “ON Until Disarm
PROGRAMMING
26 SA5
1
3
ENTER
ENTER
ENTER
ENTER
ENTER
1
3
ENTER
ENTER
ENTER
ESC
1
3
ESC
ENTER
ESC
ESC
Vista de página 27