Response SL8 Manual de Instruções Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
10
Control Panel over these screws using the two
keyhole slots in the top corners of the panel
casing.
5. Route the cable from the Power Supply Adaptor
up behind and on the right hand side of the
Control Panel and connect the plug to the DC
power socket in the panel. Ensuring that the cable
is not trapped between the panel and the wall.
6. Fix the Control Panel to the wall using two 18mm
No.4 screws in the lower two fixing holes in the
Control Panel and tighten the upper fixing screws
until they just grip the casing. Do not over-tighten
the screws as this could damage or distort the
casing.
7. Ensure that the Reset Jumper Link (P1) and the
External Tamper Switch Jumper Link (P51) are
set in the OFF position.
8. Connect battery leads to both back-up batteries
and refit batteries.
LEFT Battery: Red lead to the Red (
+
) battery
terminal
Black lead to the Black (
-
) battery
terminal
RIGHT Battery: Red lead to the Red (
+
) battery
terminal
Black lead to the Black (
-
) battery
terminal
Note: The Power LED may flash to indicate that
the unit is being operated from the back-up
batteries and that mains supply is not present.
9. Close the lid of the Control Panel and fasten the
cover fixing screws.
10. Plug in and switch ON the Power Supply Adaptor,
(the Power LED should illuminate).
LEARNING A NEW REMOTE
CONTROL/KEYPAD
Note: Up to a total of 6 Remote Controls and/or
Keypad Units can be linked to the system.
To link a new Remote Control/Keypad to the
Control Panel:
Place the Control Unit into Learn Mode. With the
system in Standby
Press
The Arm and Part-Arm LEDs will illuminate and all
Zone, Fire and Tamper LEDs will flash together.
1. Press on the Control Panel.
The Tamper LED will flash continuously to
indicate the system is in device learn mode.
The current number of Remote Controls/Keypads
already linked into the system will be indicated on
the zone LEDs. For example if there are three
Remotes/Keypad linked then zone LEDs 1, 2 and 3
will be illuminated.
The panel will now listen for valid signals from new
remote controls or keypads.
OFF ON
Jumper
Link
O. GND V+ OUT GND
External Tamper Switch
Jumper Link P51
Reset Jumper
Link P1
Jumper
Link
Jumper
Link
IMPORTANT: Take care when connecting
battery leads to the batteries as connecting
incorrectly could damage the batteries or the
Control Panel.
N
ote: If the Control Panel Tamper alarm sounds
d
uring the installation reset the alarm by pressing
on the Control
Panel.
IMPORTANT: The keys must be pressed firmly
and within 5 seconds of each other. If you make
a mistake, press and start the sequence again.
1
4
23
ENTER
, ,
User Access Code
?
?
??
ENTER
, ,
User Access Code
1
0
ESC
Note: The Panel will remain in Learn Mode for
30s. If a valid signal is not received from a new
Remote Control or Keypad within 30s it will
automatically exit Learn Mode and return to the
top level of Program Mode.