13
Unlock Module (optional)
Please refer to the instructions that accompany
the module.
IMPORTANT:
The optional unlock module must be installed by a
competent installer. Care should be taken to correctly
connect the polarity when using the optional 12 V (max)
power supply. The unlock module operates a contact
with a maximum rating of 240V 10A, which can be
used for automatic locks, switching on lighting etc.
This must be installed by a fully qualified electrician.
Please note:
When using an external power supply unit to power the Outdoor Station, the batteries
inside the Outdoor Station must be removed before connecting the power supply.
Unlock
Module
Interface
Power Supply
Output: +12V DC
300mA
Outdoor
Station
PGND
Power
CTRL
SGND
GND
12VDC
NO/ NC
Contacts
(Max. rating
240V 10A)
12VDC +
12VDC–
Loc k+
Loc k–
For activating devices,
e.g. Lock Module
Notes:
•
The terminal cover seal on the rear of the Outdoor Station is used to protect the terminal screws .
• Remove the cover to access the terminal screws when connecting the optional power supply
or unlock module.
• Remember to replace the cover prior to fixing the Outdoor Station to the fixing plate with
the fixing screw.