28
The zone 1 LED will illuminate to indicate the
current Zone Lockout status.
L
ED ON Zone Lockout enabled
LED OFF Zone Lockout disabled
To change the setting:
Press
The Zone Lockout status will switch to the
opposite state (enabled/disabled) each time the
button is pressed.
Press to
save the new setting and exit to
Program Mode, or
Press to exit without saving
.
JAMMING DETECTION
This controls the systems anti-jamming detection
facility. It is recommended that the jamming
detection is not activated for at least the first 30
days to allow time for you to become familiar with
the operation of your systems first.
Default setting: OFF (disabled)
Press
The zone 1 LED will illuminate to indicate the
current Jamming Detector status.
LED ON Jamming Detection enabled
LED OFF Jamming Detection disabled
To change the setting:
Press
The jamming detection status will switch to the
opposite state (enabled/disabled) each time the
button is pressed.
Press to
save the new setting and exit to
Program Mode, or
Press to exit without saving
.
Note: The jamming detection program setting
will only control the jamming detection feature in
the Control Panel. The jamming detection
function incorporated in the Siren operates
independently.
SPECTRA LIGHTING STATUS
Press
T
he current status of the Spectra Lighting control
f
eatures is indicated on the zone 1 LED as follow:
Spectra Lighting Control
Disabled (OFF) zone 1 LED OFF
Spectra Lighting Control
Enabled (ON) zone 1 LED ON
To change the setting:
Press
The On/Off status will switch to the opposite
state on each button press.
Press to
save the new setting and exit to
Program Mode, or
Press to exit without saving
.
SPECTRA LIGHTING TIME-ON PERIOD
Press
The current setting for the Spectra lighting time-on
period will be displayed on the zone LEDs as follow:
Time on Illuminated Selection
period LEDs Button
0 all off press
1 minute zone 1 press
2 minutes zone 2 press
3 minutes zone 3 press
5 minutes zone 4 press
10 minutes zone 5 press
20 minutes zone 6 press
To change the setting:
Press the button corresponding to the required
alarm period, the corresponding zone LED will
illuminate as the setting is changed
.
Press to
save the new setting and exit, or
Press to exit without saving
.
ZONE OPERATING MODE
Each alarm zone provides only a standard intruder
monitoring with normal Arm and Part-Arm functions.
Comentários a estes Manuais