The Entry-Delay for each zone may be configured for
between 10 to 250 seconds or disabled completely.
Note: To conserve power and maximise battery life
the PIR Detector will only detect movement if there
has been no movement detected within the previous
2 minutes. Consequently the PIR Detector will not
become active until the protected area has been
free from movement for more than 3 minutes.
ZONES
The system incorporates 32 wireless alarm zones
for the connection of a detector per zone used to
independently monitor different areas of the
property. In addition to standard intruder protection,
each zone can also be configured to operate in
alternative modes.
For example:
– ‘Intruder’ mode provides standard intruder
monitoring.
– ‘24-hour Intruder’ mode provides 24 hour intruder
protection for areas where continuous monitoring
is required, (e.g. gun lockers).
– ‘Fire’ mode provides 24 hour monitoring of any
Smoke detectors incorporated into the system.
–‘Test’ mode allows a zone to be monitored while
the system is armed. If a detector on a zone is
triggered an entry will be recorded in the Event
Log but an alarm will not occur.
In addition there is the facility to connect up to 4
hard wired zones to the Control Panel, each of which
is configurable with most of the features of the
wireless zones.
ZONE LOCKOUT
If a detector on an active zone is triggered while the
system is armed an alarm will sound. After the
programmed alarm duration has expired the alarm
will stop and the system will automatically reset.
Subsequent detectors triggered will again trigger an
alarm. If a single zone triggers an alarm more than
3 times then that zone will be ‘Locked Out’ and any
further alarm signals from that zone will be ignored
until the system is disarmed.
Note: The ‘Zone Lockout’ feature can be disabled
if required.
QUICK SET
The system may be fully armed in 10 seconds using
the quick set facility, overriding the programmed exit-
delay. This is useful for setting the system at night
when the Exit-Delay warning beep will be silenced
after just a few seconds.
EVENT LOG
The Control Panel incorporates a memory capable
of storing the last 99 system events. This enables
the user to see which user has Armed/Disarmed
the system and if and when any alarms occurred.
The time, date and details of the event type will be
recorded for each system event.
CHIME
Chime is a low security facility for use when the
system is in Standby mode. If the Chime feature is
ON, and a detector on a zone that has its Chime
function enabled is triggered, the internal sounder
will produce a low volume warning tone. A typical
use of the Chime function would be to warn that a
door or particular area has been entered.
MONITORING (OPTIONAL)
This system incorporates a telephone dialler (Voice
Dialler) and monitoring service (Remote Manager).
The monitoring service enables the system to make
a check call to the premises and generate text/email/
telephone calls/messages to up to 6 key holders.
A monitoring service provider is required to make
use of these features.
IMPORTANT: to set up monitoring follow REMOTE
MANAGER instructions.
The system telephone dialler can be set up as a
Voice Dialler that can be used to call for help and
or/notify the user that the system has been triggered
and an alarm has occurred.
In this mode the system will call for help using
your recorded message and dial up to 4 telephone
numbers and replay the corresponding alarm
message for each number. Switching the system
between
Remote Manager to Voice Dialler is
straightforward.